Typical Data | STANDARD ASTM C 155 GRADES | |||||||||
Properties | BNZ-20 | BNZ-23 | BNZ-23 HS | BNZ-23A | BNZ-26 | BNZ-26-60 | BNZ-28 | BNZ-3000 | BNZ-32 | |
ASTM Classification | 20/23 | 23 | 23 | 23 | 26 | 26 | 28 | 30 | 32 | |
Temperature Use Limit (Normal oxidizing atmosphere) |
°F °C |
2300 1260 |
2300 1260 |
2300 1260 |
2300 1260 |
2600 1427 |
2600 1427 |
2800 1538 |
3000 1649 |
3200 1760 |
Density, Avg. ASTM C 134 |
lb/ft² kg/m³ lb/BEq kg/str. |
36 577 2.1 0.9 |
37 593 2.2 1.0 |
42 673 2.5 1.1 |
33 529 1.93 0.86 |
48 769 2.8 1.3 |
50 801 2.9 1.3 |
55 881 3.2 1.5 |
65 1041 3.8 1.7 |
75 1201 4.4 2.0 |
Modulus of Rupture ASTM C 133 |
lb/in² MPa kg/cm² |
95 0.7 6.7 |
105 0.7 7.4 |
140 1.0 9.9 |
115 0.79 8 |
200 1.4 14.1 |
190 1.3 13.4 |
220 1.5 15.5 |
250 1.7 17.6 |
300 2.1 21.1 |
Cold Crushing of Strength ASTM C 133 |
lb/in² MPa kg/cm² |
105 0.7 7.4 |
125 0.9 8.8 |
190 1.3 13.4 |
145 1 10.2 |
270 1.9 19.0 |
290 2.0 20.4 |
340 2.3 23.9 |
440 3.0 31.0 |
450 3.1 31.7 |
Permanent Linear Change | % | |||||||||
ASTM C 210 | ||||||||||
24 hrs at soaking temp: °F (°C) | ||||||||||
2250 (1232) | 0.0 | 0.0 | 0.0 | 0.0 | – | – | – | – | – | |
2350 (1290) | – | – | – | – | – | – | – | – | ||
2450 (1343) | – | – | – | – | – | – | – | – | ||
2550 (1399) | – | – | – | -0.4 | -0.2 | – | – | – | ||
2750 (1510) | – | – | – | – | – | -0.7 | – | – | ||
2800 (1538) | – | – | – | – | – | – | – | – | ||
2950 (1621) | – | – | – | – | – | – | -0.7 | – | ||
3150 (1732) | – | – | – | – | – | – | – | -0.4 | ||
Reversible Linear Thermal Expansion | % | |||||||||
at 2000°F (1093°C) | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.65 | 0.65 | 0.65 | |
Hot Load Strength | % | |||||||||
ASTM C 16 | deformation | |||||||||
10 psi load for 11/2 hours: °F (°C) | ||||||||||
2000 (1093) | 0 | 0 | 0 | 0 | – | – | – | – | – | |
2200 (1204) | – | – | – | 0.2 | 0.1 | 0.1 | – | – | ||
2400 (1316) | – | – | – | – | – | – | 0.3 | 0.2 | ||
Thermal Conductivity | Btu-in/ft², hr, °F | |||||||||
ASTM C 182 | (W/mk) | |||||||||
Mean temperature, °F (°C) | ||||||||||
500 | 0.9 | 1.0 | 1.2 | .92 | 1.6 | 1.8 | 2.3 | 2.8 | 3.9 | |
(260) | 0.13 | 0.14 | 0.17 | 0.13 | 0.23 | 0.26 | 0.33 | 0.40 | 0.56 | |
1000 | 1.2 | 1.3 | 1.5 | 1.14 | 1.9 | 2.0 | 2.4 | 2.9 | 4.1 | |
(538) | 0.17 | 0.19 | 0.22 | 0.16 | 0.27 | 0.29 | 0.35 | 0.42 | 0.59 | |
1500 | 1.5 | 1.6 | 1.7 | 1.39 | 2.2 | 2.1 | 2.6 | 3.1 | 4.2 | |
(816) | 0.22 | 0.23 | 0.25 | 0.2 | 0.32 | 0.30 | 0.37 | 0.45 | 0.61 | |
2000 | 1.7 | 1.8 | 2.0 | 1.64 | 2.6 | 2.3 | 2.7 | 3.3 | 4.3 | |
(1093) | 0.24 | 0.26 | 0.29 | 0.24 | 0.37 | 0.33 | 0.39 | 0.48 | 0.62 | |
To convert Btu-in/ft², hr, °F to Kcal-m², hr, °C, multiply by 0.124. |
||||||||||
Chemical Analysis | ||||||||||
Alumina – Al2O3 | 39.4 | 39.4 | 39.4 | 38 | 47.0 | 60.4 | 67.0 | 69.9 | 78.3 | |
Silica – SiO2 | 54.9 | 54.9 | 54.9 | 45 | 49.2 | 36.1 | 30.5 | 28.1 | 20.7 | |
Ferric Oxide – Fe2O3 | 0.7 | 0.7 | 0.7 | 0.3 | 0.6 | 0.4 | 0.3 | 0.3 | 0.2 | |
Titanium Oxide – Ti2O2 | 1.5 | 1.5 | 1.5 | 1.6 | 1.3 | 1.0 | 0.9 | 1.2 | 0.5 | |
Calcium Oxide – CaO | 3.0 | 3.0 | 3.0 | 15 | 0.3 | 0.1 | 0.3 | 0.2 | 0.1 | |
Magnesium Oxide – MgO | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.2 | 0.0 | 0.1 | 0.1 | |
Alkalies, as Na2O & K2O | 0.4 | 0.4 | 0.4 | 0.5 | 1.5 | 1.8 | 1.0 | 0.2 | 0.1 |